8809267793869
01152
4 zone preamplifier (6 inputs / 4 outputs) - 230V/24V - 19" 3U
Ideal for multi-zone use such as in hotels, conference rooms, schools, sports and fitness centres.
Availability date: 11/25/2021
In Stock
Warning: Last items in stock!
Delivered within 48/72h
For professionals
To log inFor individuals
Contact usOption Microphone consoles :
The PTT 100N console is equipped with switchable chime, siren and priority functions. When the "Talk" button is pressed, the message is broadcast simultaneously in all zones. Three 100N PTT stations can be connected. The lectern is connected to the preamplifier via RJ45/Cat.5 socket (3m cable included).
The RM-400 Microphone Keypad provides remote control. The priority and chime function can be activated or deactivated. Equipped with switches to address the message to one, several or all zones. Up to 32 RM-400 stations can be addressed and connected in series up to 1.2 km long. The connection is made via CAT5 cable with RJ45 plugs.
SPECIFICATIONS | MX-604 | |
Input Sensitivity/Impedance | MIC/LINE 1~3 | 50 dBu (2,45 mV) kΩ symmetric 10 dBu (245 mV) - 15 KΩ symmetric |
LINE /REC IN | 10 dBu (245 mV) - 10 KΩ symmetric | |
Output level / Impedance | ZONE | NOR + 4 dBu (21,23 V) / 200 Ω symmetric |
REC | NOR 0 dBu (0,775 mV) 10 KΩ symmetric | |
Frequency Response | 20 Hz – 20 000 Hz – 0,5 dB | |
Signal to Noise Ratio | MICRO | > 60 dB |
LINE | > 75 dB | |
Harmonic distortion | MICRO | > 0,05 % |
LINE | > 0,03 % | |
Crosstalk | MICRO | > 60 dB |
LINE | > 75 dB | |
Power consumption 230 V | Rated power | 10 W |
Stand-by | 1 W | |
Output impedance | 70 V / 81,6 Ω 100 V / 166,6 Ω | 70 V / 40,8 Ω 100 V / 83,3 Ω |
Power supply | AC 230 V / 50 Hz / DC 24 V | |
Dimensions (L x P x h) | 483 x 377 x 88 mm (2 U) | |
Weight | 4 kg |