| PARAMETERS | VALUES |
| Main power supply | AC 100V-240V 50/60Hz |
| Rear power supply | 21.5V DC - 28.5V DC |
| Fuse | T10AH 250V |
| Power consumption | <740W |
| Push To Talk Microphone | |
| Sensitivity | -59±3dBV |
| Frequency response | 100Hz -14KHz, ±3dB |
| SNR | >50dB, A-weighted |
| Auxiliary input | |
| Number | 2 |
| Input sensitivity | 1V(0dBV) |
| Input impedance | 10 KΩ |
| Frequency response | 85Hz-18KHz, ±3dB |
| SNR | >80dB, A-weighted |
| MIC/LINE Input | |
| Input sensitivity | 5mV/1V, set by DIP switch |
| Input impedance | 20 KΩ |
| Frequency response | 80Hz-18KHz, ±3dB |
| SNR | >80dB, A-weighted |
| Phantom power output | 24V DC, set by DIP switch |
| Audio output | |
| Output channels | CH1, CH2 and recorder |
| Output signal | 1V (0dBV) |
| THD | <0.1% |
| Internal power amplifier | |
| Maximum power | 500W |
| Output signal | 100V(CH1A) |
| Frequency response | 80Hz-18KHz, ±3dB |
| THD | <0.1% |
| Power amplifier interface | |
| Number | 3 (CH1, CH2 and spare amplifier) |
| Output signal | 1.4V |
| THD | <0.1% |
| Signal monitoring | Self-test, amplifier fault and energy saving control signal |
| PARAMETERS | VALUES |
| Speaker interface | |
| Zone number | 8 (each has an A and B output) |
| Max. load power | 500W |
| Input/Output Contact | |
| Input Contact | 10 contact input interfaces with supervision |
| Output Contact | 8 contact output interfaces (NO, NC and COM), "Fault" output and "Alarm" output. |
| Maximum output voltage | AC 250V/DC 30V |
| Maximum output current | 2.5A |
| Others | |
| DC output power | 24V/1A |
| Monitor speaker | 2W/8Ω |
| Ethernet Interface | 10M/100M |
| Memory | 1 GB flash memory, 4 GB SD card |
| Operating conditions | |
| Relative humidity | <95%, non-condensing |
| Operating temperature | -10°C~+50°C |
| Storage temperature | -40°C~+70°C |
| Specification | |
| Dimensions (WxHxD) | 482 mm×133.5 mm ×420 mm |
| Packing dimensions (WxHxD) | 580 mm×279 mm ×552 mm |
| Net weight | 14.3Kg |
| Gross weight | 17.4Kg |